With this processing technique, the

u

THERM

Flat Roof BG

roof insulation boards are always installed in a crisscross pattern and in a single layer.

2-layer processing is not possible, due to the high temperatures.

5. Loose installation

The

u

THERM

Flat Roof PIR M/BG/L/BGM

insulation boards can only be applied without fasteners if the roofing and the necessary load are

installed immediately after the boards, and if the roofing can be sufficiently fixed to the edges of the roof. This also applies when terrace tiles

provide the necessary ballast load.

4. OVERVIEW OF APPLICABLE ATTACHMENT TECHNIQUES FOR UTHERM ROOF INSULATION BOARDS, DEPENDING ON THE TYPE OF

SUBSURFACE

Mechanical

attachment

Cold glueing

Glueing with

synthetic glue

Hot

glueing

Loose

(ballasted)

W

o

o

d

L

M

BG

BGM

M

BGM (M side)

L

M

BGM (M side)

BG

BGM (BG side)

L

M

BG

BGM

C

o

n

c

r

e

t

e

L

M

BG

BGM

M

BGM (M side)

L

M

BGM (M side)

BG

BGM (BG side)

L

M

BG

BGM

S

t

e

e

l

L

M

BG

BGM

M

BGM (M side)

L

M

BGM (M side)

BG

BGM (BG side)

L

M

BG

BGM

5. APPLICATION OF A ROOF SEALANT

Type of roof sealant

Fastening method

APPLICATION SURFACE

Concrete

Steel

Wood

Bituminous roof sealant

layer

Partial glueing according to the

pouring method for hot bitumen

BG

BGM (BG side)

BG

BGM (BG side)

BG

BGM (BG side)

Bituminous roof sealant

layer

Partial glueing according to the

torch-applying method

BG

BGM (BG side)

M

1

– L

1

BG

BGM (BG side)

M

1

– L

1

BG

BGM (BG side)

M

1

– L

1

Bituminous roof sealant

layer

Full-surface glueing with cold

glue

BGM (M side)

M

BGM (M side)

M

BGM (M side)

M

Bituminous roof sealant

layer

Self-glueing

BGM (M-side)²

M² – L

3

BGM (M-side)²

M² – L

3

BGM (M-side)²

M² – L

3

EPDM

Full-surface glueing with cold

glue or synthetic glue

B – L – M

B – L – M

B – L – M

PVC

Full-surface glueing with

synthetic glue

L – M

L – M

L – M

Sealing layer

Loosely installed with a ballast

layer

B

4

– L – M

B

4

– L – M

B

4

– L – M

Sealing layer

Mechanically attached

B

4

– L – M

B

4

– L – M

B

4

– L – M

1

2-layer bituminised roofing. Top layer torched-on.

2

The manufacturer of the self-glueing membrane must provide information on the suitability of his product.

3

Solution is dependent on the used roofing system. Contact Unilin for more information.

4

If a PVC sealing layer is used, then a separating layer must be applied according to the regulations of the manufacturer.